HY-CDSSU Series Capacitor Charge And Discharge Special Power Source,It is used in capacitor manufacturers, capacitor use units and capacitor detection and measurement Unit, can be DV/DT test.
The method is to charge the measured capacitor first and measure the DV/DT value during the rapid discharge of the capacitor. The signal voltage, frequency and discharge resistance can be set according to the needs, the signal is applied to both ends of the measured capacitor, the test period is set, and the capacitor is continuously tested. During the test, the temperature rise, capacity and loss of the capacitor are constantly monitored and recorded. Finally, according to the temperature rise of the capacitor and the change of capacity and loss, whether the capacitor meets the requirements is judged.
Using this method to detect, whether it is the characteristics of the material (polarization characteristics), or the difference in structural design (plate resistance) and the difference in loss, it can be directly reflected by the temperature rise of the capacitor and the change in capacity loss.
Product Features
■ Input voltage:220VAC50Hz
■ Output voltage:0-2000VrmsContinuously adjustable (custom accepted)
■ Output capacity:200VA-10kVA
■ Charge and discharge test current:0~3000A (Custom accepted)
■ The actual voltage on the product under test needs to be detected and displayed (at the frequency of 1kHz, the average voltage of every 10 charges is taken and displayed; The machine trigger time is about 300mS) to determine whether the product is fully charged; If there is no voltage, the alarm signal should be output
■ Trigger mode can be switched manually and automatically; How long it is triggered and how long the device should work continuously
■ Charge and discharge frequency:0.5k/1kHz (Accept customization)
■ Discharge resistance:0Ω
■ 10U single machine size and weight:440(W)*600(D)*445(H)mm,About 47kg
■ For more parameters, please refer to the sample booklet